Die u:cris Detailansicht:

Investigation of novel preclinical Total Body PET designed with J-PET technology: A simulation study

Autor(en)
M. Dadgar, S. Parzych, F. Tayefi Ardebili, J. Baran, N. Chug, C. Curceanu, E. Czerwinski, K. Dulski, K. Eliyan, A. Gajos, B. C. Hiesmayr, K. Kacprzak, L. Kaplon, K. Klimaszewski, P. Konieczka, G. Korcyl, T. Kozik, W. Krzemien, D. Kumar, S. Niedzwiecki, D. Panek, E. Perez del Rio, L. Raczynski, S. Sharma, Shivani, R. Y. Shopa, M. Skurzok, K. Tayefi Ardebili, S. Vandenberghe, W. Wislicki, E. L. Stepien, P. Moskal
Abstrakt

The growing interest in human-grade total body positron emission tomography (PET) systems has also application in small animal research. Due to the existing limitations in human-based studies involving drug development and novel treatment monitoring, animal-based research became a necessary step for testing and protocol preparation. In this simulation-based study two unconventional, cost-effective small animal total body PET scanners (for mouse and rat studies) have been investigated in order to inspect their feasibility for preclinical research. They were designed with the novel technology explored by the Jagiellonian-PET (J-PET) Collaboration. Two main PET characteristics: sensitivity and spatial resolution were mainly inspected to evaluate their performance. Moreover, the impact of the scintillator dimension and time-of-flight on the latter parameter was examined in order to design the most efficient tomographs. The presented results show that for mouse TB J-PET the achievable system sensitivity is equal to 2.35% and volumetric spatial resolution to 9.46 ± 0.54 mm

3, while for rat TB J-PET they are equal to 2.6% and 14.11 ± 0.80 mm

3, respectively. Furthermore, it was shown that the designed tomographs are almost parallax-free systems, hence, they resolve the problem of the acceptance criterion tradeoff between enhancing spatial resolution and reducing sensitivity.

Organisation(en)
Quantenoptik, Quantennanophysik und Quanteninformation
Externe Organisation(en)
Jagiellonian University in Krakow, National Centre for Nuclear Research (NCBJ), Ghent University , INFN - Laboratori Nazionali Di Frascati
Journal
IEEE Transactions on Radiation and Plasma Medical Sciences
Band
7
Seiten
124-131
Anzahl der Seiten
8
ISSN
2469-7311
DOI
https://doi.org/10.1109/TRPMS.2022.3211780
Publikationsdatum
10-2022
Peer-reviewed
Ja
ÖFOS 2012
302054 Nuklearmedizin
Schlagwörter
ASJC Scopus Sachgebiete
Instrumentation, Atomic and Molecular Physics, and Optics, Radiology Nuclear Medicine and imaging
Link zum Portal
https://ucrisportal.univie.ac.at/de/publications/8725e484-9075-421e-be2a-22f4f682a521