The role of ions in condensation particle counting for particle diameters below 2nm

Autor(en)
Paul Winkler, Aron Vrtala, Paul Wagner
Abstrakt

Condensation particle counting for particle diameters below 2 nm may be influenced by the simultaneous presence of ions depending on the experimental procedure. Neutralization of electrostatically classified aerosols by means of a 241Am bipolar diffusion charger causes comparatively high number concentrations of positive and negative ions which enter the measuring chamber simultaneously to the particle species of interest. In this paper we illustrate how the presence of ions influences the measured particle number concentration and how a removal of ions allows to measure number concentration of seed particles correctly.

Organisation(en)
Aerosolphysik und Umweltphysik
Seiten
73-77
Anzahl der Seiten
5
DOI
https://doi.org/10.1007/978-1-4020-6475-3_14
Publikationsdatum
2007
ÖFOS 2012
103020 Oberflächenphysik, 105204 Klimatologie, 210006 Nanotechnologie, 103029 Statistische Physik
Link zum Portal
https://ucrisportal.univie.ac.at/de/publications/84825397-c63a-46cb-8293-f2fd63bb5419